Login
The accreditation demonstrates technical competence for the scope described in the Technical Annex and operating a Quality Management System.
The purpose of the Quality of Laboratory CENCAL System is to satisfy customer needs. We seek that this principle guides in our activity by responding as quickly as possible to requests, providing appropriate responses to their needs.
Accredited tests and respective delivery time are the following (see Anexo Técnico L0008-1):
Determination of lead and cadmium released by ceramic ware, glass and other materials in contact with food: |
EN 1388-2; EN 1388-1; ISO 6486-1; ASTM C 927; ASTM C 738 |
3 days |
Determination of water absorption of ceramic articles. |
EN 1217 - Method A and B |
2 days |
Crazing Resistance of Ceramic Articles – Autoclave treatment. |
EN 13258 - Method A |
8 days |
Resistance to thermal shock of ceramic articles |
EN 1183 - Method B |
3 days |
Resistance to mechanical removal of ceramic decorations in dishwashers. |
EN 12875-4 | 3 days |
Resistance to microwave heating of ceramic glass and glass-ceramic. | BS EN 15284 | 2 days |
In addition to the accredited testing, Laboratory CENCAL provides other services to companies in the ceramic sector:
Testing of the Ceramic Process Control
In this context, to study the possibility of defects or faults, carries out tests to raw materials, and ceramic glazes, determination of physical properties such as texture, bulk density, porosity, mechanical strength, shrinkage, rheology, etc.
Control Finished Product (Tableware, Ovenware and Pottery)
A clear understanding to Laboratory of the client request is the first step to start tests. The customer is informed about the number of samples to be sent to the laboratory for each type of test, the delivery schedule and the respective price.
Tests are performed in accordance with national or international standards and when applicable, standard according to internal rules. The laboratory is available to perform tests in accordance with procedures submitted by the customer.
The results are presented in clear and rigorous test reports in portuguese, english or french as requested by the client, and then sent to the customer within the agreed time getting the technical team on hand to help the client to interpret the results expressed therein.
All client information is confidential. The activity is performed by qualified and experienced technicians according to the highest standards of impartiality and transparency.
A) Ensaios Físicos (Análises disponíveis no imediato)
Cód. |
Designação |
Campo de Aplicação |
Nº Amostras |
Especificação/Método |
Tempo Estimado por análise |
Observações |
A.1 |
Determinação do teor de humidade |
Matérias primas Composição |
200 g |
ASTM C324 |
Próprio dia a 1 dia |
Amostra representativa de vários pontos do carregamento. |
A.2 |
Análise Granulométrica |
Matérias primas |
200 g |
ASTM C371 |
Próprio dia a 1 dia |
Amostra representativa de vários pontos do carregamento. |
A.3 |
Determinação da densidade |
Vidro |
1 peça de vidro |
Procedimento interno de murça e corda. |
Próprio dia a 1 dia |
Amostra de vidro recozido, isenta |
A.4 |
Determinação do grau de recozimento |
Vidro |
6 peças de vidro |
ASTM C 671-94; 218-95; C148-95 |
Próprio dia a 1 dia |
Amostra de vidro recozido, isenta de murça e corda. |
A.5 |
Determinação da resistência ao choque térmico |
Vidro |
6 peças de vidro |
NP 3314 |
Próprio dia a 1 dia |
Amostra de vidro recozido, isenta de murça e corda. |
A.6 |
Determinação da resistência ao ataque de detergentes |
Vidro |
6 peças de vidro |
ASTM C676 |
Próprio dia a 1 dia |
Amostra de vidro recozido, isenta de murça e corda. |
A.7 |
Determinação do coeficiente de dilatação (α) |
Vidro/Outro |
Provete cilíndrico |
NP 3681-1990 |
1 a 2 dias |
|
A.8 |
Determinação %Minerais Pesados |
Areia |
5Kg |
Separação Gravítica |
4 dias |
|
B) Ensaios Químicos (Análises disponíveis no imediato)
Cód. |
Designação |
Campo de Aplicação |
Amostras |
Especificação/Método |
Tempo Estimado de análise |
Observações |
B.1 |
Determinação da % Carbonatos solúveis na mistura vitrificável (homogeneidade) |
Composição (mist. Vitrificável) |
200 g |
Adap. INII 23 |
1 dia |
Amostra recolhida à saída do misturador (composição) |
B.2 B.2.2 |
Análise Química Det. Ferro (Fe2O3) |
Vidro |
100 g |
ASTM C169 ASTM C146 |
2 dias |
Amostra vidro recozido
|
B.2.3 |
An. Completa (SiO2,CaO,MgO,Fe2O3,Na2O,K2O, Al2O3,BaO,PbO,CdO,Cr2O3) |
ASTM C169 |
4 dias |
|||
B.2.4 |
Det. teores (CaO,MgO,Fe2O3,Na2O,K2O, Al2O3,BaO,PbO,CdO,Cr2O3) |
ASTM C169 |
2 dias |
|||
B.2.5 |
Det. Chumbo |
EAA |
2 dias |
|||
B.2.6 |
Det. Sílica |
ASTM C 146 |
2 dias |
|||
B.2.7 |
Det. de um elemento |
EAA |
1 dias |
|||
B.2.8 |
Det. Cádmio |
EAA |
2 dias |
|||
B.2.11 |
Det. % ferro em soluções |
Soluções |
100 ml |
EAA |
Próprio dia a 1 dia |
Soluções concentração conhecida |
B.2.12 |
Det. % ferro outras matérias primas |
matérias primas |
100 g |
EAA |
Próprio dia a 1 dia |
Amostra representativa de vários pontos do carregamento |
INII - instituto nacional de investigação industrial
EAA - Espectrofotómetro absorção atómica
B.3 B.3.1 |
Análise Química Det. Perda ao rubro | areia | 100g | NP 1766 | 2 dias | Areia: amostra representativa de vários pontos do carregamento |
B.3.2 | Det. Ferro (Fe2O3) | ASTM C169 | 2 dias | |||
B.3.3 | Análise Completa (SiO2,CaO,MgO,Fe2O3,Na2O,K2O,Al2O3) |
ASTM C146 ASTM C169 |
4 dias | |||
B.3.4 | Det. teores (CaO,MgO,Fe2O3,Na2O,K2O, Al2O3) | ASTM C169 | 2 dias | |||
B.3.6 | Det. Sílica | ASTM C146 | 2 dias | |||
B.3.7 | Det. de um elemento | ASTM C169 | 2 dias | |||
B.4. B.4.1 |
Análise Química Det. Perda ao rubro | Calcário | 100g | NP 176 | 2 dias | Amostra representativa de vários pontos do carregamento |
B.4.2 | Det. Fero (Fe2O3) | ASTM C169 | 2 dias | |||
B.4.3 | Análise Completa (CaO,MgO,Fe2O3,Na2O,K2O, Al2O3) | Complexometria e ASTM C169 | 4 dias | |||
B.4.4 | Det. teores (CaO,MgO,Fe2O3) | Complexometria e ASTM C169 | 4 dias | |||
B.4.8 | Det. Resíduo Insolúvel | Proc. Interno | 2 dias |
B.5 B.5.1 |
Análise Química Det. Perda ao rubro |
Dolomite |
100 g |
|
|
Amostra representativa de vários pontos do carregamento.
|
NP 1766 |
2 dias |
|||||
B.5.2 |
Det. Ferro (Fe2O3) |
ASTM C169 |
2 dias |
|||
B.5.3 |
Análise Completa (CaO,MgO,Fe2O3,Na2O,K2O, Al2O3) |
Complexometria e ASTM C169 |
4 dias |
|||
B.5.4 |
Det. teores (CaO,MgO,Fe2O3) |
Complexometria e |
4 dias |
|||
B.5.8 |
Det. Resíduo Insolúvel |
Proc.Interno |
2 dias |
|||
B.6 B.6.1 |
Análise Química Det. Pureza |
Carbonato Sódio |
100 g |
INII 22 e INII 23 |
2 dias |
|
B.6.2 |
Det. Ferro (Fe2O3) |
ASTM C169 |
2 dias |
|||
B.6.8 |
Det. Resíduo Insolúvel |
Proc.Interno |
2 dias |
|||
B.7 B.7.1 |
Análise Química Det. Pureza |
Carbonato Potássio |
100 g |
INII 22 e INII 23 |
2 dias |
|
B.7.2 |
Det. Ferro (Fe2O3) |
ASTM C169 |
2 dias |
|||
B.8 |
Análise Química |
Carbonato Bário |
100 g |
INII 22 e INII 23 |
2 dias |
|
B.8.1 |
Det. Pureza Det. Ferro (Fe2O3) |
|||||
B.8.2 |
ASTM C169 |
2 dias |
||||
B.9.8 |
Det. Resíduo Insolúvel |
Sulfato Sódio |
100 g |
Proc.Interno |
2 dias |
B.10 |
Análise Química Análise Completa (SiO2,CaO,MgO,Fe2 O3,Na2O,K2O,Al2O3) |
Feldspato |
100 g |
ASTM C146 |
4 dias |
Amostra representativa de vários pontos do carregamento
|
B.10.3 |
ASTM C169 |
|||||
B.11 |
Análise QuímicaAnálise Completa (SiO2,CaO,MgO,Fe2 O3,Na2O,K2O,)
|
Escórias
|
100 g
|
ASTM C146 |
4 dias |
|
B.11.3 |
ASTM C169 |
|||||
B.12 B12.2 |
Análise Completa Det. Ferro (Fe2O3) |
Outras matérias primas
|
100g |
ASTM C169 |
2 dias |
|
ASTM C169 |
4 dias |
|||||
B.13 |
Det. da resistência hidrolítica |
Vidro |
3 peças (idênticas) |
ASTM C225 DIN 52329 |
4 dias |
Amostras de vidro recozido |
B.15 |
Det. dos teores de chumbo e cádmio solúveis da superfície (embalagem para alimentos ou bebidas) |
Vidro (cristal, artigos com corantes de cádmio ou decorados) |
6 peças (idênticas) |
NP 2094 |
4 dias |
|
B.16 |
Det. dos teores de chumbo e cádmio no bordo de peças (embalagem para alimentos ou bebidas) |
Vidro (cristal, artigos com corantes de cádmio ou decorados) |
6 peças (idênticas) |
ASTM C927 |
4 dias |
(+) - Se capacidade dos recipientes inferior a 168 ml, formar 3 conjuntos com cerca de 100 ml.
Os prazos indicados de respostas são estimados, podendo sofrer ligeiras dilatações, consoante o volume de análises e ensaios a efectuar. Os nossos métodos de ensaio baseiam-se em procedimentos normalizados.